Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Magnetic Amplifier				
			 
			
										
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						60.0 hertz  single component					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Open					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						4 single group					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Slot single group					
				 
							
					
						MRC:
						The amount of control current beyond which an increase in control current produces no increase in the items output.CHTZ
					 
					
						Saturation Current Rating:
					
					
						100.0 milliamperes					
				 
							
					
						MRC:
						The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
					 
					
						Dc Resistance Rating In Ohms:
					
					
						100.800 single component 3rd control					
				 
							
					
						MRC:
						The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
					 
					
						Dc Resistance Rating In Ohms:
					
					
						900.800 single component 1st control					
				 
							
					
						MRC:
						The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
					 
					
						Dc Resistance Rating In Ohms:
					
					
						900.800 single component 2nd control					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						129.00 dc pounds per hour wet single component single winding					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						2.00 dc pounds per hour wet single component 1st winding and 4.00 dc pounds per hour wet single component 1st winding					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						12 wire lead