Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, astm a216, grade wcb
First End Flange Outside Diameter:
5.500 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
Stem Material:
Steel, corrosion resisting
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Raised face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Raised
First End Raised Face Height:
0.061 inches
First End Raised Face Diameter:
2.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
First End Flange Shape Style:
Round w/ bolt holes
MRC:
A measurement of the smallest dimension of the first end flange, in distinction from length or width.ACKU
First End Flange Thickness:
0.688 inches
MRC:
The number of bolt holes provided on the item.ACKZ
First End Bolt Hole Quantity:
6
MRC:
The length of a straight line which passes through the center of a bolt hole,and terminates at the circumference.ACLA
First End Bolt Hole Diameter:
0.719 inches
First End Bolt Circle Diameter:
4.250 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Steel, corrosion resisting
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Stem and integral disk
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel, corrosion resisting
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
1st stage automatic, 2nd stage manual
MRC:
The means used to manually adjust the item.AEVP
Manual Control Method:
Wheel
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Dome
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
450.0 degrees fahrenheit
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
This item has been reviewed for asbestos material the current approved sources 35795 have indicated their part number contained asbestos prior to 1984.They continue to manufacture the same part number without asbestos material after 1984