Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
High function layer switch
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
14.750 inches
MRC:
The commercial and government entity (cage) code of the government agency,industrial organization,or other source,which controls the document.AJJY
Document Source:
64034
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Alternate operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
180.0 ac volts 2nd operating power rqmt and 264.0 ac volts 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
90.0 ac volts 1st operating power rqmt and 132.0 ac volts 1st operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 63.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+32.0/+104.0 degrees fahrenheit
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Fuse
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
3.0 ac amperes 1st operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
1.7 ac amperes 2nd operating power rqmt
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Automatic warning at 140 degf; 4 amp fuse; storage temp minus 22 degf to 149 degf; up to 90 percent noncondensing humidity