Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Includes 15.0 ft air hose, inflator kit and 6.0 ft power cord
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Reciprocating Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
1.700 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
90.0 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Single
MRC:
The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
Compressed Gas Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Hand carry
MRC:
The reciprocating compressor design as determined by the mechanical action by which compression takes place in the cylinder/s/ of the compressor.AAXY
Reciprocating Compressor Design:
Single acting
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the angular arrangement of the cylinders.AAYA
Cylinder Arrangement Style:
Horizontal design
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
A measurement of the longest dimension of an item unencumbered by packaging or packing,in distinction from width.AJAF
Unpackaged Unit Length:
14.500 inches
MRC:
A measurement taken at right angles to the length of an item unencumbered by packaging or packing,in distinction from thickness.AJAG
Unpackaged Unit Width:
9.500 inches
MRC:
A measurement from the bottom to the top of an item unencumbered by packaging or packing,in distinction from depth.AJAH
Unpackaged Unit Height:
10.000 inches
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of control device provided.BDML
Control Device Type:
Manual speed regulator
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac
MRC:
The brake power required to start and operate the item including all accessories at the actual rated capacity,expressed in unit of power.CXNT
Brake Power Required:
0.5 horsepower
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0