Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Circuit Breaker				
			 
			
										
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Plastic					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.138 inches 					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						2 unthreaded hole					
				 
							
					
						MRC:
						Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
					 
					
						Storage Type:
					
					
						General purpose warehouse					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						100.0 milliamperes ac single location and 100.0 milliamperes dc single location					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						240.0 ac single location and 24.0 dc single location					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Overcurrent single location					
				 
							
					
						MRC:
						The means by which the trip mechanism is released.CPRJ
					 
					
						Trip Release Method:
					
					
						Magnetic single location					
				 
							
					
						MRC:
						Denotes the type of trip release action.CPRL
					 
					
						Trip Release Characteristic:
					
					
						Time delay single location					
				 
							
					
						MRC:
						The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
					 
					
						Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
					
					
						125.0 single location					
				 
							
					
						MRC:
						The means provided to reposition the mechanism so that the device is ready to function.CPRQ
					 
					
						Reset Method:
					
					
						Manual					
				 
							
					
						MRC:
						Indicates the type of mechanism provided for tripping main contacts.CPRR
					 
					
						Main Contact Tripping Mechanism Type:
					
					
						Trip free					
				 
							
					
						MRC:
						Indicates the type and number of actuators provided for manual control.CPRT
					 
					
						Manual Actuator Type And Quantity:
					
					
						1 push button					
				 
							
					
						MRC:
						Denotes the action imparted by actuator operation.CPRW
					 
					
						Actuator Function:
					
					
						Trip-reset					
				 
							
					
						MRC:
						An indication of the designated position of the actuator.CPRX
					 
					
						Actuator Position Designation:
					
					
						At pole one					
				 
							
					
						MRC:
						The function for which the auxiliary switch is designed and the number provided.CPRZ
					 
					
						Auxiliary Switch Function And Quantity:
					
					
						1 control					
				 
							
					
						MRC:
						The basic internal electrical configuration of the trip mechanism.CPSM
					 
					
						Internal Trip Release Configuration:
					
					
						Series trip single location					
				 
							
					
						MRC:
						Indicates the location of the switch in relation to its designated position.CQSM
					 
					
						Switch Location And Position Designation:
					
					
						External at pole one					
				 
							
					
						MRC:
						The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
					 
					
						Trip Delay Time In Seconds Per Rated Continuous Current:
					
					
						15.000  at 200 pct single location and 40.000  at 200 pct single location					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0 single location					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 tab,  solder lug