Discharge/charge the esm storage power supply (pn 4000-12000); providesa variable resistive load to ac/dc converter (pn 4000-11000); monitor voltage and current; interface power supply to battery box; provide charge monitoring status; supply 40 amp dc load for the ac/dc converter; provides separate digital displays for voltage and current along with a variable current control; includes front panel test points for external monitoring
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
19.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
17.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
220.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Electrical load bank, 3 ea, pn 4000-20000-01; cables, pn 4000-19400-01; battery charge/discharge fixture, pn 4000-19530-01; cooling fixture, pn 400019510-01; test panel assembly, pn 4000-19600-01
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Electronic warfare systems, power supply/sps (pn 4000-10000)
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Fault isolation/test
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Metered variable current, dc load for testing power supplies
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
58.000 inches
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Operates in conjunction with 2 hppower supplies (not included), pn 6264b and 6456b; ambient temperature: p32 to p125 degrees fahrenheit; altitude: sea level to 13000 ft; humidity: 20 to80 pct within operating temperature