Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
40125
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
005817231
NSN
Nationale Bestandsnummer:
5930-00-581-7231 5930005817231
TXT
Beschreibung:
Pressure Switch
INC
INC
Artikelname-Code:
00206
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.400 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.510 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.120 inches
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
2.625 inches
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
2.000 inches
MRC:
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
Pressure Switch Type:
Gage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
27 single pressure connection
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.125 inches single pressure connection
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position rectangular
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, both positions maintained
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Connector, receptacle
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
5.0 amperes resistive load single voltage
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
1.00 differential point pounds per square inch
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
30.0 dc at sea level single voltage
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt single pressure connection