Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.562 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.688 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.438 inches single mounting facility single center group
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.250 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
47.0 hertz single component and 63.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield grounded to core single component
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
130.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 2 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
2.0 milliamperes ac single component 2nd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1.0 amperes ac single component 1st secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
1.2 volts-amperes single component 2nd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
16.0 volts-amperes single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
16.00 ac pounds per hour wet single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
117.00 ac pounds per hour wet single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
6.00 ac pounds per hour wet single component 2nd secondary