Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Impedance measurement range: 10.0 megohms to 120.0 kilohms; phase measurement range: plus 180.0 degrees to minus 180.0 deg
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Ohmmeter
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.600 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.750 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.0 hertz and 66.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Elec. Test equip
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Low ground probe kit which contains a probe, spare pins, clips, bnc adapter, component mounting adapter, probe socket, and accessory case
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench
MRC:
The hue or tint of the background.AQFY
Background Color:
Black single indicator single range
MRC:
Indicates the type of display provided.BFQN
Display Type:
Light emitting diode
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
3-1/2
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+400.0/+110000.0 kilohertz single indicator single range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
3.0 pct of reading single indicator single range
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
1 plug and 1 test prod
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
100.0 ac and 120.0 ac and 220.0 ac and 240.0 ac
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Measures spot or swept frequency; measure impedance magnitude and phase; test components in-circuit and out-of-circuit; standard hp-ib and analog outputs
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
D1 rectangular or square