Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						42-100364-01					
 
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electronic Frequency Converter				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						13.180 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						0.950 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						5.800 inches 					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						+50.0 to 2000.0					
				 
							
					
						MRC:
						The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
					 
					
						Vibration Resistance Amplitude:
					
					
						1.5 gravitational units					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Rectangular or square					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The increase in energy from the input to the output.BHTL
					 
					
						Overall Gain:
					
					
						21.0 decibels					
				 
							
					
						MRC:
						Indicates the type and number of indicator device(s) included.BJBL
					 
					
						Indicator Device Type And Quantity:
					
					
						1 audible alarm					
				 
							
					
						MRC:
						The maximum time an item will continuously run,expressed in hours.BJBM
					 
					
						Maximum Continuous Operating Time In Hours:
					
					
						168.0					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						15.0  single voltage