Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Incubator bacteriological 10to65deg c range ac 120/230v 700w
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Bacteriological Incubator				
			 
			
										
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						Between 50.0 hertz and 60.0 hertz 					
				 
							
					
						MRC:
						An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
					 
					
						Inside Width:
					
					
						18.000 inches 					
				 
							
					
						MRC:
						An outside measurement taken at right angles to the length of an item,in distinction from thickness.ADJV
					 
					
						Outside Width:
					
					
						20.000 inches 					
				 
							
					
						MRC:
						An inside measurement between specified points of an item,in distinction from height.AFEF
					 
					
						Inside Depth:
					
					
						17.000 inches 					
				 
							
					
						MRC:
						An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
					 
					
						Inside Height:
					
					
						24.000 inches 					
				 
							
					
						MRC:
						An outside measurement from the bottom to the top of an item,in distinction from depth.AFMW
					 
					
						Outside Height:
					
					
						76.000 inches 					
				 
							
					
						MRC:
						The value(s) of potential for which the item is rated.AMSE
					 
					
						Voltage Rating:
					
					
						120.0 volts  and 230.0 volts 					
				 
							
					
						MRC:
						The amount of electrical energy that can be dissipated.ANPT
					 
					
						Power Rating:
					
					
						700.0 watts 					
				 
							
					
						MRC:
						Indicates the type of control.AQZF
					 
					
						Control Type:
					
					
						Temperature control dial and thermostat					
				 
							
					
						MRC:
						The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
					 
					
						Operating Tempurature Range In Deg Celsius:
					
					
						+10.0/+65.0					
				 
							
					
						MRC:
						The heat source for which the item is designed.AZZH
					 
					
						Heat Source For Which Designed:
					
					
						Integral					
				 
							
					
						MRC:
						An outside measurement between specified points on an item,in distinction from height.BCXB
					 
					
						Outside Depth:
					
					
						20.000 inches 					
				 
							
					
						MRC:
						The means by which the item is heated.BDWT
					 
					
						Heating Method:
					
					
						Electrical					
				 
							
					
						MRC:
						An indication of whether or not the item is provided with a water jacket.BGXH
					 
					
						Water Jacket:
					
					
						Not provided					
				 
							
					
						MRC:
						The number of shelves furnished with the item.BGZL
					 
					
						Shelf Quantity:
					
					
						12					
				 
							
					
						MRC:
						An indication of whether or not the shelf(ves) is adjustable.BGZM
					 
					
						Shelf Adjustability:
					
					
						Adjustable					
				 
							
					
						MRC:
						The means used to provide circulation.BHGT
					 
					
						Circulation Method:
					
					
						Gravity					
				 
							
					
						MRC:
						An indication of whether or not an insulated cabinet is provided.BLST
					 
					
						Insulated Cabinet:
					
					
						Provided					
				 
							
					
						MRC:
						The element,compound,or mixture of which the shelf is fabricated,excluding any surface treatment.BPYK
					 
					
						Shelf Material:
					
					
						Steel,  stainless					
				 
							
					
						MRC:
						The element,compound,or mixture of which the cabinet outer wall is fabricated,excluding any surface treatment.BQMH
					 
					
						Cabinet Outer Wall Material:
					
					
						Steel					
				 
							
					
						MRC:
						The element,compound,or mixture of which the cabinet inner wall is fabricated,excluding any surface treatment.BQMJ
					 
					
						Cabinet Inner Wall Material:
					
					
						Steel,  stainless					
				 
							
					
						MRC:
						The number of outer doors included.BQMN
					 
					
						Outer Door Quantity:
					
					
						2					
				 
							
					
						MRC:
						The element,compound,or mixture of which the outer door is fabricated,excluding any surface treatment.BQMP
					 
					
						Outer Door Material:
					
					
						Metal					
				 
							
					
						MRC:
						An indication of whether or not an outer door insulation feature is included.BQMR
					 
					
						Outer Door Insulation Feature:
					
					
						Not included					
				 
							
					
						MRC:
						The number of inner doors included.BQMS
					 
					
						Inner Door Quantity:
					
					
						2					
				 
							
					
						MRC:
						The element,compound,or mixture of which the inner door is fabricated,excluding any surface treatment.BQMT
					 
					
						Inner Door Material:
					
					
						Glass					
				 
							
					
						MRC:
						An indication of whether or not a vacuum chamber is included.BQWN
					 
					
						Vacuum Chamber:
					
					
						Not included					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Single					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Dual chambered vertical carbon dioxide incubator;  each chamber independently regulated, providing separate hot wall heating, humidity and co2 tension for microbiological cultures which require varying environments;  automatic or manually controlled;  flow rate from 0.06 to 0.44 liters per min