Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Four 0.215 in. Diameter mtg holes; n female connector; copper housing with nickel plating
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrical Dummy Load
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
-55.0 and 95.0
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.371 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
0.875 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.060 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
Impedance Rating In Ohms:
50.0
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.625 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.060 inches
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+0.000/+200.000 megahertz
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.30
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
500.000 kilowatts peak
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+0.000/+200.000 megahertz
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
All positions
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Self-cooled
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rf connector, 4 hole mounted