Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
43531-345-00-7
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Antenna
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
196.500 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
118.000 megahertz all antennas and 135.000 megahertz all antennas
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Rain tight and dustproof and fungus proof
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Radio control, air/ground (rcag)
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
N all antennas
MRC:
The design of the connector end.AHUD
Connector End Design:
Socket all antennas
MRC:
The orientation of the electrical vector of energy radiated from the item relative to the line of propagation.AJCT
Electromagnetic Polarization Type:
Vertical all antennas
MRC:
The graphical representation of the radiation pattern of the device as a function of direction.AJCU
Radiation Pattern:
Omnidirectional all antennas
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
50.000 watts peak all antennas
MRC:
The reactance-resistance complex value which must be matched by the transmission line and termination to achieve lowest standing wave ratio,expressed in ohms.AJDD
Characteristic Impedance In Ohms:
50.0 all antennas
MRC:
The means used to direct a beam/s/ of energy successively over a given region.AJDH
Beam Scanning Method:
Fixed all antennas
MRC:
Indicates the design type of the item.APGF
Design Type:
Collinear array all antennas and dipole all antennas
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Receptacle, coaxial all antennas
MRC:
The ratio of the signal intensity of an item radiated in a specific direction to the signal intensity radiated in the same direction by a standard device,expressed in decibels.CTMN
Power Gain In Decibels:
1.00 all antennas