Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Pressure Switch				
			 
			
										
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.229 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the horizontal plane.AFDS
					 
					
						Longest Horizontal Distance Between Mounting Centers:
					
					
						Between 1.580 inches and 1.600 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the vertical plane.AFDV
					 
					
						Longest Vertical Distance Between Mounting Centers:
					
					
						Between 3.360 inches and 3.380 inches 					
				 
							
					
						MRC:
						The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
					 
					
						Pressure Switch Type:
					
					
						Absolute					
				 
							
					
						MRC:
						The temperature at which the item operates.AWTN
					 
					
						Operating Tempurature Rating:
					
					
						Between -65.0 degrees fahrenheit and 180.0 degrees fahrenheit 					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Bracket and unthreaded hole					
				 
							
					
						MRC:
						An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
					 
					
						Contact Action Stimulus:
					
					
						Increase					
				 
							
					
						MRC:
						The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.CQJB
					 
					
						Proof Pressure:
					
					
						40.00 inches of mercury					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Four position rectangular					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						2 pole,  double throw,  one position momentary					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						5.0 amperes resistive load single voltage and 2.0 amperes inductive load single voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Actuation point not adjustable					
				 
							
					
						MRC:
						The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
					 
					
						Contact Stimulus Rating:
					
					
						6.71 actuation point  inches of mercury					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						28.0 dc at sea level single voltage					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Gas