Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electromagnetic Relay				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.500 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						1.562 inches  single mounting facility					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.400 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						1.400 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Plastic					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.168 inches  single mounting facility and 0.174 inches  single mounting facility					
				 
							
					
						MRC:
						The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.AFRG
					 
					
						Contact Material:
					
					
						Silver					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						6525-01-159-3009;  end item name:  field radiopgraphic/fluoroscopic x-ray system;  model dxd 350					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.AJSS
					 
					
						Frequency In Hertz:
					
					
						Between 50.0 and 60.0 					
				 
							
					
						MRC:
						The number of coils included on the item.APCN
					 
					
						Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 unthreaded hole single mounting facility					
				 
							
					
						MRC:
						The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.AYSC
					 
					
						Pile-up Main Contact Form Arrangement:
					
					
						2c					
				 
							
					
						MRC:
						A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
					 
					
						Cubic Measure:
					
					
						4.900 cubic inches					
				 
							
					
						MRC:
						The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
					 
					
						Operating Current Rating And Type:
					
					
						5.0 amperes ac all windings and 3.0 amperes ac all windings					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						5.0 amperes ac resistive load					
				 
							
					
						MRC:
						The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
					 
					
						Main Contact Maximum Voltage Rating In Volts:
					
					
						250.0 ac					
				 
							
					
						MRC:
						An indication of the precious material and its location in the item.PMLC
					 
					
						Precious Material And Location:
					
					
						Cross-bars gold and contacts silver					
				 
							
					
						MRC:
						Identification of the precious material contained in the item.PRMT
					 
					
						Precious Material:
					
					
						Gold and silver					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						11 tab,  solder lug all functions