Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Ups system tower
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Uninterruptible Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.000 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Magnetic shield and dripproof
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
On-line double-conversion ups tower system; simultaneous communications via hid-compliant usb port, serial port and snmp/web slot card; fault-tolerant auto-bypass
MRC:
The number of batteries required for operation.AEXR
Battery Quantity:
1
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Mission-critical applications
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
9.0 ohms single power output
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
2.0 single power output
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
110.0 dc volts single operating power rqmt and 120.0 dc volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
110.0 ac volts single power output and 120.0 ac volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz single operating power rqmt and 60.0 hertz single operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
50.0 hertz single power output and 60.0 hertz single power output
MRC:
Indicates the type of load for which the item is designed.ASCX
Load Type:
Resistive single power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 single power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage range single power output
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
1600.0 watts single power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Reverse voltage protection and remote error sensing capability
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2200.0 ac amperes single power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Single single power output
MRC:
The output waveform of the current at the output terminals.CWGS
Output Waveform And Current Type:
Full wave rectified sine wave ac single power output
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Constant current single power output and constant voltage single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
7 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Solder lug single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
16.0 dc amperes single operating power rqmt and 17.6 dc amperes single operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Connector, plug single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 single operating power rqmt
MRC:
An indication of whether or not the battery is rechargeable and the type of battery.CWHY
Battery Feature And Type:
Iso precision class 10 head outside diameter
MRC:
Indicates the location of the battery.CWJF
Battery Location:
External
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Single fan
MRC:
The time required for a power supply(ies) to reach the full operating potential for which it is rated,expressed in minutes.CWKM
Warm Up Time In Minutes:
0
MRC:
The time required to charge a battery(ies) to its rated capacity after a period of discharge.CWWB
Battery Recovery Time:
5.0
MRC:
The program(s) for which the power supply is design compatible.CWWJ
Program Compatibility:
Watchdog compatibility
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
99.0
MRC:
The power supply operational efficiency when connected to a battery(ies).CWWZ
Power Supply Efficiency Battery:
99.0
MRC:
The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
Battery Power Supply Emergency Operating Time:
4.5 and 14.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Black smart online expandable tower ups system
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Tested to ul177 (usa), csa(canada), nom(mexico), class a(emissions) fcc part 68/industry canada, rohs compliant