Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Varidrive-synchrogear speed control
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Aircraft Generator Test Stand
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Floor
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of current for which the blower unit motor is designed.AELA
Blower Unit Motor Current Type:
Ac
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Dual head
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Portable test panel
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
15.0
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The minimum to maximum limits at which examination of an item is performed at low speed,expressed in revolutions per minute.CHGS
Err Default:
Err default
MRC:
The minimum to maximum limits at which examination of an item is performed at low speed,expressed in revolutions per minute.CHGS
Low Speed Test Range In Rpm:
+1100.0 to 5500.0
MRC:
The minimum to maximum limits at which examination of an item is performed at high speed,expressed in revolutions per minute.CHGT
Err Default:
Err default
MRC:
The minimum to maximum limits at which examination of an item is performed at high speed,expressed in revolutions per minute.CHGT
High Speed Test Range In Rpm:
+2400.0 to 12000.0
MRC:
The length of a straight line which passes through the center of the maximum generator the item is designed to accommodate,and terminates at the circumference.CHGX
Maximum Generator Diameter Accommodated:
6.000 inches
MRC:
An indication of the generator voltage range and current type the item is designed to accommodate.CHGY
Generator Voltage Range In Volts And Current Type Accommodated:
+0.0/+120.0 ac and +15.0/+30.0 dc
MRC:
The maximum generator output current the item is designed to accommodate,expressed in amperes.CHGZ
Maximum Generator Output In Amps Accommodated:
300.0
MRC:
An indication of whether or not a driving motor transmission is included.CHHB
Driving Motor Transmission:
Included
MRC:
The number of speeds provided.CHHC
Err Default:
Err default
MRC:
The number of speeds provided.CHHC
Speed Quantity:
2
MRC:
An indication of whether or not an electric motor blower is included.CHHD
Electric Motor Blower:
Included
MRC:
The value,or range of values,of potential for which the blower motor is rated,expressed in volts.CHHF
Blower Motor Voltage In Volts:
Between 220.0 and 330.0
MRC:
The number of blower motor alternating current phases.CHHH
Err Default:
Err default
MRC:
The number of blower motor alternating current phases.CHHH
Blower Motor Phase:
Three
MRC:
The cycles per second (hertz) of the blower motor alternating current.CHHJ
Err Default:
Err default
MRC:
The cycles per second (hertz) of the blower motor alternating current.CHHJ
Blower Motor Frequency In Hertz:
60.0
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
220.0 and 440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0