MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
Heat exchange 1020 btu min; 60 gal per min water flow through cooler; 3.5 psi water pressure drop in cooler; 18 gpm engine oil flow; 215 degrees f oil temp from cooler; 8 psi oil pressure drop in cooler; 10.440 in. Cooler lg o/a, 4.880 in. W o/a; 2.620 in. Radius of ends; 4.810 in. H, 16 plates, six 0.348 in. Diameter holes on outer edge of cooler; all hole spaced 2.090 in. From parallel center line to hole centers, 3 holes on each side spaced 2.880 in. C to c; one hole centered at each end; 0.760 in. C to c; two 1.000 in. Diameter holes holes centered and spaced @7.060 in. C to c