Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Rotary Pump				
			 
			
										
					
						MRC:
						The number of intake connections included on the item.AAYT
					 
					
						Intake Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of intake connection included on the item.AAYU
					 
					
						Intake Connection Type:
					
					
						Threaded internal					
				 
							
					
						MRC:
						The number of discharge connections included on the item.AAYV
					 
					
						Discharge Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of discharge connection included on the item.AAYW
					 
					
						Discharge Connection Type:
					
					
						Threaded internal					
				 
							
					
						MRC:
						Indicates the type of connection between the prime mover and the shaft.AAYX
					 
					
						Drive Connection Type:
					
					
						Rigid coupled					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Hydrocarbon fuels and oils					
				 
							
					
						MRC:
						The maximum rated capacity delivered by the item.AHYV
					 
					
						Maximum Discharge Flow Rate:
					
					
						22.0 gallons per minute					
				 
							
					
						MRC:
						The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
					 
					
						Discharge Pressure:
					
					
						50.0 pounds per square inch gage					
				 
							
					
						MRC:
						The speed of the item required to produce its rated capacity.AHYZ
					 
					
						Operating Speed At Rated Capacity:
					
					
						1200.0 revolutions per minute					
				 
							
					
						MRC:
						The position in which the pumping element/s/ is designed to operate.AHZA
					 
					
						Pumping Element Operating Position:
					
					
						Horizontal					
				 
							
					
						MRC:
						The means by which the item is operated.AHZT
					 
					
						Operation Method:
					
					
						Powered					
				 
							
					
						MRC:
						Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
					 
					
						Drive Shaft Type:
					
					
						Woodruff keyway					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the drive shaft end,and terminates at the circumference.AJAC
					 
					
						Drive Shaft End Diameter:
					
					
						Between 0.7488 inches and 0.7490 inches 					
				 
							
					
						MRC:
						A measurement of the distance the drive shaft extends from the housing.AJAD
					 
					
						Drive Shaft Length:
					
					
						5.156 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of an item unencumbered by packaging or packing,in distinction from width.AJAF
					 
					
						Unpackaged Unit Length:
					
					
						8.800 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of an item unencumbered by packaging or packing,in distinction from thickness.AJAG
					 
					
						Unpackaged Unit Width:
					
					
						9.500 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of an item unencumbered by packaging or packing,in distinction from depth.AJAH
					 
					
						Unpackaged Unit Height:
					
					
						9.500 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of the basic material of which the major portion of the pump is fabricated.AJAL
					 
					
						Pump Basic Material:
					
					
						Iron					
				 
							
					
						MRC:
						Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
					 
					
						Discharge Connection Thread Size And Series/type Designator:
					
					
						1.000-11-1/2 npt					
				 
							
					
						MRC:
						Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
					 
					
						Intake Connection Thread Size And Series/type Designator:
					
					
						1.000-11-1/2 npt