Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Axial Pistons Pump Unit
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
1
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydrocarbon fuels and oils
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Piston
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
16.9 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
15.2 pounds per square inch gage
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
1800.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The reciprocating design of the pump.AHZJ
Pump Reciprocating Design:
Single acting
MRC:
Indicates the type of reciprocating movement within the item.AHZN
Reciprocating Stroke Type:
Variable