Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
504-7729-004
Informationen zum Teil
W/hinged cover, power section, audio and control section
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Distribution Panel
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
3.750 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The rated power that an item can safely consume or provide,measured in watts.ABJL
Wattage Rating In Watts:
Any acceptable
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.500 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Rack
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no. An/grc-27
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Junction for connecting as power from the mains, audio and control circuits between components of an/grc-27
MRC:
The name designation of the written or printed document.ALYQ
Document Title:
Components and accessories listed in dept army supply manual sig 7 and 8
MRC:
The element,compound,or mixture of which the panel is fabricated,excluding any surface treatment.ANJG
Panel Material:
Aluminum
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single
MRC:
The number of complete cyclic changes,per unit of time,for which the output frequency is rated.ANSQ
Output Frequency Rating:
60 hertz
MRC:
The number of panels provided.APCA
Panel Quantity:
1
MRC:
The number of electrical inputs accommodated.APNW
Electrical Input Quantity:
1
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour dry and 230.0 ac pounds per hour with retaining chain
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
Between 115.0 ac volts and 230.0 ac volts
MRC:
An indication of whether or not an input neutral is provided.APNY
Input Neutral:
Provided
MRC:
The number of electrical outputs provided.APNZ
Electrical Output Quantity:
1
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
Between 115.0 ac volts and 230.0 ac volts
MRC:
The rated output power that an item can safely consume or provide,measured in watts.APPB
Output Wattage Rating In Watts:
Any acceptable
MRC:
An indication of whether or not an output neutral is provided.APPC
Output Neutral:
Provided
MRC:
The cycles per second /hertz/ of input alternating current.APPY
Input Frequency In Hertz:
Any acceptable
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Painted