Teilenummer 504

Oscilloscope
Beschreibung

Case

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
504
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
000664384
NSN
Nationale Bestandsnummer:
6625-00-066-4384 6625000664384
TXT
Beschreibung:
Oscilloscope
INC
INC
Artikelname-Code:
00357
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
21.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
14.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
1 adapter, conn, 1 filter, light, crt, 2 manual, technical
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 volts and 230.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
1
MRC:
The interval/s/ as indicated by the markings on the item.AWEC
Graduation Interval:
Graduated in v/cm on both axes
MRC:
The means of attaching the item.AXGY
Mounting Method:
Portable
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-3.0/+3.0
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-3.0 to 3.0
MRC:
Designates the relative or proportionate dimensions of the screen.BGQK
Screen Size:
5 in.
MRC:
An indication of whether or not an expanded sweep is provided.BGSD
Expanded Sweep:
Not provided
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Provided
MRC:
The value,or range of values,for which the vertical deflection sensitivity is rated.BHDF
Vertical Deflection Sensitivity Voltage Rating:
0.0045 volts rms per inch and 18.0000 volts rms per inch
MRC:
The value,or range of values,for which the horizontal deflection sensitivity is rated.BHDG
Horizontal Deflection Sensitivity Voltage Rating:
0.45 volts any acceptable outside diameter
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Not provided
MRC:
An indication of whether or not provisions for rating the direct connection to the plate deflection sensitivity is provided.BHDL
Plate Direct Connection Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Provided
MRC:
The minimum and maximum frequencies to which the y-axis will respond.BHDR
Y-axis Frequency Response Rating:
Between 0.0 kilohertz and 450.0 kilohertz
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Provided
MRC:
The total opposition (resistive and reactive) which the item offers to the y-axis input flow of alternating current.BHDX
Y-axis Input Impedance Rating:
1.0 megohms
MRC:
An indication of the shape of the amplitude calibrating voltage waveform.BHDZ
Amplitude Calibrating Voltage Waveform:
Square wave
MRC:
The peak to peak value for which the item is calibrated.BHFB
Calibrating Peak To Peak Amplitude:
Between 25.0 millivolts and 500.0 millivolts
MRC:
The number of measurement ranges included.BHFC
Measurement Range Quantity:
2
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Not included
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Oscilloscope, except specially designed

Ähnlich Oscilloscopes

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken