Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrical Dummy Load
MRC:
The amount of coolant necessary to maintain the required operating temperature of the item.AAXT
Cooling System Coolant Flow Rate:
2.0 gallons per minute
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.875 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.000 inches
MRC:
The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
Impedance Rating In Ohms:
50.0
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+0.060/+2.000 gigahertz
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10 and 1.15 and 1.20
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Tnc
MRC:
The design of the connector end.AHUD
Connector End Design:
Female
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
5.000 kilowatts peak
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+0.000/+1.000 gigahertz and +1.000/+1.500 gigahertz and +1.500/+2.000 gigahertz
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connection coaxial
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
All positions
MRC:
The nominal outward force,per unit of area,of the coolant chamber.AWNJ
Coolant Chamber Pressure:
150.0 pounds per square inch gage
MRC:
The input temperature of the coolant.AWNL
Input Coolant Temp:
90.0 degrees celsius
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Forced liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Coaxial mounted