Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Ceramic Diele Variable Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rotary
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.175 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.218 inches
MRC:
The center to center distance between terminals parallel to the diameter of the item.AEBS
Center To Center Distance Between Terminals Parallel To Diameter:
0.195 inches
MRC:
The ratio of capacitive reactance to resistance,expressed at 25 degrees celsius.AECJ
Quality Factor At 25 Deg Celsius:
350.0
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The measurement of the mechanical motion of the adjustment device.AXGJ
Adjustment Device Rotation:
180.0 degrees clockwise
MRC:
The torque required for the adjustment device.AXGR
Adjustment Device Torque:
Between 0.500 inch-ounces and 3.000 inch-ounces
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 terminal
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 85.0 degrees celsius
MRC:
The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
Capacitance Range In Picofarads:
+2.0 to 5.0 single section
MRC:
The highest potential and type that may be applied to the item,at the highest operating temperature permissible without voltage derating.CTGP
Nonderated Voltage Rating And Type:
100.0 dc continuous single section
MRC:
The limits of capacitance change in percent at operating temperature from a stated value at 25 degrees celsius.CTGQ
Capacitance Change In Percent At Operating Tempurature From 25 Deg Celsius:
-1.75 to 8.00 and -9.50/+2.80 single section
MRC:
The limits of capacitance change in percent at operating temperature from a stated value at 25 degrees celsius.CTGQ
Capacitance Change In Percent At Operating Tempurature From 25 Deg Celsius:
-1.75 to 8.00 and -9.50 to 2.80 single section
MRC:
Indicates the type and number of drive(s) provided for the adjustment device.CTGR
Adjustment Device Drive Type And Quantity:
1 slotted screw
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 tab, solder lug