Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Digital Reado Electronic Counter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.250 inches
MRC:
The rated power that an item can safely consume or provide,measured in watts.ABJL
Wattage Rating In Watts:
40.0
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.469 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
4
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Bnc
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Hewlett packard co
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
5223l model no.
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Counter, electronic, digital readout
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Cp-1033/u
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 115.0 volts and 230.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
Between 0.1 kilohertz and 100.0 kilohertz
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
2
MRC:
The means of attaching the item.AXGY
Mounting Method:
Rack or bench
MRC:
The name of the accessory component assigned by the controlling agency.AZCG
Accessory Component Name:
Two 4 ft cables with male bnc connectors, detachable power cord, two circuit board extenders, rack mount conversion kit
MRC:
Indicates the type of measurement provided.BFHZ
Measurement Type:
Frequency and ratio and period average
MRC:
The range of complete cyclic changes,per unit of time,for which the item is rated.BFJB
Frequency Range:
+0.000 to 300.000 kilohertz and +0.000 to 300.000 kilohertz f1 input ratio and +0.000 to 300.000 kilohertz f2 input ratio and +0.000 to 100.000 kilohertz single period and +0.000 to 300.000 kilohertz multiple period
MRC:
An indication of the deviation from a standard or true value for which the item is rated.BFJC
Accuracy Rating:
Porm 1 count, porm time base porm 1 count of f1, porm trigger error of f2 multiplier setting porm 1 count time base porm trigger error
MRC:
The interval of time during which the item provides a signal.BFJF
Gate Time:
Between 0.000000010 seconds and 10.000000000 seconds
MRC:
The rated sensitivity of the item.BFJG
Sensitivity Rating:
0.1 vrms sine wave, 1 v pulse, 1 v min width
MRC:
The visual presentation of the ratio information.BFQH
Ratio Display:
F1/f2 to 1000 f1/f2 depending on multiplier setting
MRC:
The minimum and maximum number of periods.BFQJ
Period Range:
+10.0 to 10000000.0
MRC:
The number of period range steps provided.BFQK
Period Range Step Quantity:
7 decade steps
MRC:
An indication of the count rate of the item.BFQL
Count Rate:
0.0001 kilohertz multiple period and 100.0000 kilohertz multiple period
MRC:
An indication of whether or not an internal calibration feature is included.BFQM
Internal Calibration Feature:
Included
MRC:
Indicates the type of display provided.BFQN
Display Type:
Rectangular nixie tube
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
5
MRC:
An indication of whether or not a display units indicator is included.BFQQ
Display Units Indicator:
Included
MRC:
An indication of whether or not a display positioned decimal point is provided.BFQR
Display Positioned Decimal Point:
Provided
MRC:
An indication of whether or not a display storage facility is included.BFQS
Display Storage Facility:
Included
MRC:
An indication of whether or not provisions for remote control are included.BFQT
Remote Control Provisions:
Not included
MRC:
An indication of whether or not a solid state feature is included.BFQW
Solid State Feature:
Included
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment,and its location.BFQX
Inclosure Material And Location:
Aluminum case
MRC:
An indication of whether or not a provision for plug-in units is included.BFQZ
Plug-in Units Provision:
Not included
MRC:
An indication of whether or not a standard frequency/ies/ output feature is included.BFRB
Standard Frequency Output Feature:
Included
MRC:
An indication of the allowable frequency accuracy or stability of the item.BFRC
Frequency Accuracy/stability:
2 parts/10, 000, 000/week
MRC:
The shape of the output frequency waveform.BFRD
Output Frequency Waveform:
Sinusoidal
MRC:
The maximum absolute value of the frequency output pulse.BFRF
Frequency Output Amplitude:
1.0 volts peak to peak and 5.0 volts peak to peak
MRC:
The number of alternating current phases.FAAZ
Phase:
Single