Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						526-9745-010					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Evacuation tube on one end of item
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Band Pass Filter				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.800 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.500 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
					 
					
						Body Outside Diameter:
					
					
						0.450 inches 					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						+10.0/+55.0					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-30.0/+85.0 degrees celsius					
				 
							
					
						MRC:
						The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
					 
					
						Reference Frequency Per Function:
					
					
						455.0 kilohertz blank					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						20.0 kilohms blank					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						20.0 kilohms blank					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Mechanical blank					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 clamp					
				 
							
					
						MRC:
						The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
					 
					
						Insertion Loss At Reference Frequency Per Function In Decibels:
					
					
						3.0 blank					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 tab,  solder lug ground 3rd function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 tab,  solder lug input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 tab,  solder lug output 2nd function					
				 
							
					
						MRC:
						The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
					 
					
						Specified Frequencies Of Discrimination Per Function:
					
					
						453.00 kilohertz blank and 454.50 kilohertz blank and 455.50 kilohertz blank and 457.00 kilohertz blank					
				 
							
					
						MRC:
						The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
					 
					
						Frequency Band Width Per Function:
					
					
						454.50 kilohertz blank and 455.50 kilohertz blank					
				 
							
					
						MRC:
						The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
					 
					
						Discrimination At Specificationified Frequencies Per Function In Decibels:
					
					
						60.0  blank and 6.0  blank and 6.0  blank and 60.0  blank					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Round terminal/terminals on opposite surfaces