Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Hydraulic Motor
MRC:
The ability of an item to withstand a specified torque load without fracture.AAPL
Torque Load Rating:
454.0 inch-pounds
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Face
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
16
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.344 inches
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
4
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
3750.0
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Splined, straight internal
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise
MRC:
Indicates the location of the thread on the item.APJC
Thread Location:
Internal and internal and internal
MRC:
The number of connections furnished.ASMM
Connection Quantity:
1 and 1 and 1
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Inlet and outlet and drain
MRC:
The maximum rated working pressure of an item at a specified temperature range.AXFB
Maximum Working Pressure Rating At Specificationified Tempurature Range:
3000psi at minus 2 degrees c to plus 32 degrees c
MRC:
The design of the connection.AXFC
Connection Design:
Threaded and threaded and threaded
MRC:
A measurement of the longest dimension of a spline,in distinction from width.AXFH
Spline Length:
0.910 inches
MRC:
Indicates the displacement type.AXFP
Displacement Type:
Constant
MRC:
An indication of the constant displacement per revolution.AXFQ
Constant Displacement Per Revolution:
0.950 cubic inches
MRC:
The government specification and/or standard that specifically covers the connection.AZFE
Connection Government Specification/std:
Inlet/outlet per ms33649-10, drain per ms33649-6
MRC:
The spacing in the arrangement of the mounting bolt holes.AZFG
Mounting Bolt Hole Spacing:
4 .344 in. Diameter mtg holes on 3.536 by 3.536 in mtg centers