Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Dimensions: length 5.200 maximum by 4.250 square
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Hydraulic Motor
MRC:
The ability of an item to withstand a specified torque load without fracture.AAPL
Torque Load Rating:
175.2 inch-pounds
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Face
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
12
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
4
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
3860.0
MRC:
The length of a straight line which passes through the center of a mounting bolt circle,and terminates at the circumference.AFFL
Mounting Bolt Circle Diameter:
Between 0.343 inches and 0.350 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
E/i an/slq-48 simsl, (for sima use only); and vehicle, submersible mine locator, (mns); next assemblies: 5266000, 6097300 and 6916045
MRC:
A measurement indicating the diameter-pitch per specific measurement scale of the item.AGJS
Pitch Diameter:
0.600 inches
MRC:
The element,compound,or mixture of which the housing is fabricated.AJLF
Housing Material:
Aluminum
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Counterclockwise
MRC:
A measurement of the spline pitch of the item.ASAP
Spline Pitch:
20/40
MRC:
The number of connections furnished.ASMM
Connection Quantity:
3
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Drain
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Inlet
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Outlet
MRC:
The maximum rated working pressure of an item at a specified temperature range.AXFB
Maximum Working Pressure Rating At Specificationified Tempurature Range:
3000psi at plus 28.4 degrees f to plus 89.6 degrees f
MRC:
The design of the connection.AXFC
Connection Design:
Threaded
MRC:
The pressure angle of the spline,expressed in degrees.AXFG
Spline Pressure Angle In Deg:
30.0
MRC:
Indicates the displacement type.AXFP
Displacement Type:
Constant
MRC:
An indication of the constant displacement per revolution.AXFQ
Constant Displacement Per Revolution:
0.367 cubic inches
MRC:
The government specification and/or standard that specifically covers the connection.AZFE
Connection Government Specification/std:
33649-4 and 33649-8
MRC:
The spacing in the arrangement of the mounting bolt holes.AZFG
Mounting Bolt Hole Spacing:
3.536 in. By 3.536 in.