Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Digital Reado Electronic Counter				
			 
			
							
										
					
						MRC:
						The name assigned to the item by the joint electronics type designation system.AKWA
					 
					
						Joint Electronics Type Designation System Item Name:
					
					
						Counter, electronic digital readout					
				 
							
					
						MRC:
						The type number assigned to the item by the joint electronics type designation system.AKWB
					 
					
						Joint Electronics Type Designation System Item Type Number:
					
					
						Cp-814a/usm-207					
				 
							
					
						MRC:
						Indicates the type of measurement provided.BFHZ
					 
					
						Measurement Type:
					
					
						Frequency and period average and ratio					
				 
							
					
						MRC:
						The range of complete cyclic changes,per unit of time,for which the item is rated.BFJB
					 
					
						Frequency Range:
					
					
						+0.000/+100.000 megahertz 					
				 
							
					
						MRC:
						An indication of the deviation from a standard or true value for which the item is rated.BFJC
					 
					
						Accuracy Rating:
					
					
						Porm 1 count porm time base					
				 
							
					
						MRC:
						The interval of time during which the item provides a signal.BFJF
					 
					
						Gate Time:
					
					
						Between 0.0000001 seconds and 0.1000000 seconds 					
				 
							
					
						MRC:
						The rated sensitivity of the item.BFJG
					 
					
						Sensitivity Rating:
					
					
						F1 input 0.01v rms into 50 ohms					
				 
							
					
						MRC:
						The visual presentation of the ratio information.BFQH
					 
					
						Ratio Display:
					
					
						F1/f2 times period multiplier					
				 
							
					
						MRC:
						The minimum and maximum number of periods.BFQJ
					 
					
						Period Range:
					
					
						+0.0/+1000000.0					
				 
							
					
						MRC:
						The minimum and maximum number of periods.BFQJ
					 
					
						Period Range:
					
					
						+0.0 to 1000000.0					
				 
							
					
						MRC:
						An indication of whether or not a solid state feature is included.BFQW
					 
					
						Solid State Feature:
					
					
						Included