Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Digital Reado Electronic Counter				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						16.750 inches 					
				 
							
					
						MRC:
						The rated power that an item can safely consume or provide,measured in watts.ABJL
					 
					
						Wattage Rating In Watts:
					
					
						50.0					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						3.468 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						11.250 inches 					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						Between 50.0 hertz and 60.0 hertz 					
				 
							
					
						MRC:
						The value(s) of potential for which the item is rated.AMSE
					 
					
						Voltage Rating:
					
					
						115.0 volts  or 230.0 volts 					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Bench					
				 
							
					
						MRC:
						Indicates the type of measurement provided.BFHZ
					 
					
						Measurement Type:
					
					
						Frequency and period average and ratio					
				 
							
					
						MRC:
						The range of complete cyclic changes,per unit of time,for which the item is rated.BFJB
					 
					
						Frequency Range:
					
					
						+0.000/+50.000 megahertz f1 input ratio and +0.000/+50.000 megahertz f2 input ratio and +0.000/+10.000 megahertz single period					
				 
							
					
						MRC:
						The range of complete cyclic changes,per unit of time,for which the item is rated.BFJB
					 
					
						Frequency Range:
					
					
						+0.000/+50.000 megahertz f1 input ratio and +0.000 to 50.000 megahertz f2 input ratio and +0.000 to 10.000 megahertz single period					
				 
							
					
						MRC:
						An indication of the deviation from a standard or true value for which the item is rated.BFJC
					 
					
						Accuracy Rating:
					
					
						Porm time base for freq and period measurement, porm trigger error for ratio measurement					
				 
							
					
						MRC:
						The interval of time during which the item provides a signal.BFJF
					 
					
						Gate Time:
					
					
						0.1 microseconds 					
				 
							
					
						MRC:
						The rated sensitivity of the item.BFJG
					 
					
						Sensitivity Rating:
					
					
						0.1v rms sine wave					
				 
							
					
						MRC:
						The visual presentation of the ratio information.BFQH
					 
					
						Ratio Display:
					
					
						Fa/fext times period multiplier					
				 
							
					
						MRC:
						The minimum and maximum number of periods.BFQJ
					 
					
						Period Range:
					
					
						+1.0/+100000000.0					
				 
							
					
						MRC:
						Indicates the type of display provided.BFQN
					 
					
						Display Type:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The number of digits displayed.BFQP
					 
					
						Display Digit Quantity:
					
					
						8					
				 
							
					
						MRC:
						An indication of whether or not provisions for remote control are included.BFQT
					 
					
						Remote Control Provisions:
					
					
						Included					
				 
							
					
						MRC:
						An indication of whether or not a solid state feature is included.BFQW
					 
					
						Solid State Feature:
					
					
						Included					
				 
							
					
						MRC:
						The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment,and its location.BFQX
					 
					
						Inclosure Material And Location:
					
					
						Aluminum body					
				 
							
					
						MRC:
						Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the inclosure surface,and its location.BFQY
					 
					
						Inclosure Surface Treatment And Location:
					
					
						Enamel body					
				 
							
					
						MRC:
						An indication of whether or not a provision for plug-in units is included.BFQZ
					 
					
						Plug-in Units Provision:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a standard frequency/ies/ output feature is included.BFRB
					 
					
						Standard Frequency Output Feature:
					
					
						Not included					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Single					
				 
							
					
						MRC:
						The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
					 
					
						Fsc Application Data:
					
					
						Test set, radar