All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
5330a
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
001067524
NSN
Nationale Bestandsnummer:
6625-00-106-7524 6625001067524
TXT
Beschreibung:
Digital Reado Electronic Counter
INC
INC
Artikelname-Code:
26835
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.750 inches
MRC:
The rated power that an item can safely consume or provide,measured in watts.ABJL
Wattage Rating In Watts:
35.0
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.469 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
11.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Bnc
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 115.0 volts and 230.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
1.0 megahertz
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
2
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bench
MRC:
Indicates the type of measurement provided.BFHZ
Measurement Type:
Frequency and period average and ratio
MRC:
The range of complete cyclic changes,per unit of time,for which the item is rated.BFJB
Frequency Range:
+0.000/+10.000 megahertz multiple period and +0.001/+2.000 megahertz multiple period and +0.000/+10.000 megahertz multiple period and +0.000/+2.000 megahertz multiple period
MRC:
The range of complete cyclic changes,per unit of time,for which the item is rated.BFJB
Frequency Range:
+0.000/+10.000 megahertz multiple period and +0.001 to 2.000 megahertz multiple period and +0.000 to 10.000 megahertz multiple period and +0.000/+2.000 megahertz multiple period
MRC:
An indication of the deviation from a standard or true value for which the item is rated.BFJC
Accuracy Rating:
Porm 1 count, porm time base; porm 1 count, porm time base error, porm trigger error; porm 1 count of f1, porm trigger error of f2
MRC:
The interval of time during which the item provides a signal.BFJF
Gate Time:
Between 0.000001 seconds and 100.000000 seconds
MRC:
The rated sensitivity of the item.BFJG
Sensitivity Rating:
F1 same as input amplifier, f2 1v rms sine wave into 1000 ohms
MRC:
The visual presentation of the ratio information.BFQH
Ratio Display:
F1 times mn/f2, time mode f2 times n/f1 times m
MRC:
The minimum and maximum number of periods.BFQJ
Period Range:
+1.0/+100000.0
MRC:
The number of period range steps provided.BFQK
Period Range Step Quantity:
5 decade steps
MRC:
An indication of the count rate of the item.BFQL
Count Rate:
1.0 hertz single period and 10000000.0 hertz single period
MRC:
An indication of whether or not an internal calibration feature is included.BFQM
Internal Calibration Feature:
Included
MRC:
Indicates the type of display provided.BFQN
Display Type:
Numeric readout tube
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
5
MRC:
An indication of whether or not a display units indicator is included.BFQQ
Display Units Indicator:
Not included
MRC:
An indication of whether or not a display positioned decimal point is provided.BFQR
Display Positioned Decimal Point:
Not provided
MRC:
An indication of whether or not a display storage facility is included.BFQS
Display Storage Facility:
Included
MRC:
An indication of whether or not provisions for remote control are included.BFQT
Remote Control Provisions:
Included
MRC:
An indication of whether or not a solid state feature is included.BFQW
Solid State Feature:
Included
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment,and its location.BFQX
Inclosure Material And Location:
Aluminum case
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the inclosure surface,and its location.BFQY
Inclosure Surface Treatment And Location:
Enamel case
MRC:
An indication of whether or not a provision for plug-in units is included.BFQZ
Plug-in Units Provision:
Not included
MRC:
An indication of whether or not a standard frequency/ies/ output feature is included.BFRB
Standard Frequency Output Feature:
Included
MRC:
An indication of the allowable frequency accuracy or stability of the item.BFRC
Frequency Accuracy/stability:
5 parts per 10, 000, 000 per month
MRC:
The shape of the output frequency waveform.BFRD
Output Frequency Waveform:
Sine wave
MRC:
The maximum absolute value of the frequency output pulse.BFRF
Frequency Output Amplitude:
3.0 volts peak to peak
MRC:
The number of alternating current phases.FAAZ
Phase:
Single