Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Ceramic Diele Variable Capacitor				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Rotary					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						0.330 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
					 
					
						Shaft Diameter:
					
					
						0.100 inches  single shaft					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft,in distinction from width.ABXF
					 
					
						Shaft Length:
					
					
						0.055 inches  single shaft					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						0.375 inches 					
				 
							
					
						MRC:
						A constant that represents the proportionate change in capacitance caused by a change in temperature,expressed in parts per million per degree celsius.AEBC
					 
					
						Tempurature Coefficient Of Capacitance In Ppm Per Deg Celsius:
					
					
						-650.0 single section					
				 
							
					
						MRC:
						The center to center distance between terminals parallel to the diameter of the item.AEBS
					 
					
						Center To Center Distance Between Terminals Parallel To Diameter:
					
					
						0.363 inches 					
				 
							
					
						MRC:
						The ratio of capacitive reactance to resistance,expressed at 25 degrees celsius.AECJ
					 
					
						Quality Factor At 25 Deg Celsius:
					
					
						500.0					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encapsulated					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						2 terminal					
				 
							
					
						MRC:
						The temperature/s/ at which an item can function without voltage derating.CQJJ
					 
					
						Nonderated Operating Temp:
					
					
						Between -55.0 degrees celsius and 85.0 degrees celsius 					
				 
							
					
						MRC:
						Indicates the type of shaft included on the item.CRSJ
					 
					
						Shaft Type:
					
					
						Round,  slotted single shaft					
				 
							
					
						MRC:
						The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
					 
					
						Capacitance Range In Picofarads:
					
					
						+2.0/+8.0 single section					
				 
							
					
						MRC:
						The highest potential and type that may be applied to the item,at the highest operating temperature permissible without voltage derating.CTGP
					 
					
						Nonderated Voltage Rating And Type:
					
					
						200.0 dc continuous single section					
				 
							
					
						MRC:
						Indicates the type and number of drive(s) provided for the adjustment device.CTGR
					 
					
						Adjustment Device Drive Type And Quantity:
					
					
						1 shaft					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						39870-42498 drawing (this is the basic governing drawing,  such as a contractor drawing,  original equipment manufacturer drawing,  etc.;  excludes any specification,  standard or other document that may be referenced in a basic governing drawing)					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 tab,  solder lug