Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electronic Chopper				
			 
			
										
					
						MRC:
						The number of terminals for providing electrical connection to the item.AARA
					 
					
						Terminal Quantity:
					
					
						7					
				 
							
					
						MRC:
						Indicates the type of terminals for providing electrical connection to the item.AARB
					 
					
						Terminal Type:
					
					
						Solder lug/stud					
				 
							
					
						MRC:
						The provision/s/ for mounting the item.ABDR
					 
					
						Mounting Provision:
					
					
						Holes					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						1.406 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.625 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						0.937 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Metal					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-65.0/+125.0 degrees celsius					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						2					
				 
							
					
						MRC:
						The pattern or arrangement that describes the mounting configuration of the item.ALGC
					 
					
						Mounting Configuration:
					
					
						2 mtg holes, 0.125 in. Dia. 1.124 in. C to c					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the contact configuration.APFR
					 
					
						Contact Arrangement:
					
					
						Single pole,  double throw					
				 
							
					
						MRC:
						The input value/s/,or range of values,for which the item is rated.APNX
					 
					
						Input Voltage Rating:
					
					
						12.0 ac pounds per hour wet					
				 
							
					
						MRC:
						The input value/s/,or range of values,for which the item is rated.APNX
					 
					
						Input Voltage Rating:
					
					
						12.0 ac volts 					
				 
							
					
						MRC:
						Indicates the type of unit.APQB
					 
					
						Unit Type:
					
					
						Electronic					
				 
							
					
						MRC:
						Designates the size of the mounting facility.AWYX
					 
					
						Mounting Facility Size:
					
					
						0.125 in. Dia					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Flange					
				 
							
					
						MRC:
						An indication of whether or not a hermetically sealed feature is provided.AXNN
					 
					
						Hermetically Sealed Feature:
					
					
						Not provided					
				 
							
					
						MRC:
						An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
					 
					
						Drive Voltage Relationship To Input Voltage:
					
					
						Unequal					
				 
							
					
						MRC:
						The value,or range of values,for which the drive is rated.BGRC
					 
					
						Drive Voltage Rating:
					
					
						6.3 ac pounds per hour wet					
				 
							
					
						MRC:
						The value,or range of values,for which the drive is rated.BGRC
					 
					
						Drive Voltage Rating:
					
					
						6.3 ac volts 					
				 
							
					
						MRC:
						An indication of whether the drive current is the same as,or diffrent from,the input current.BGRD
					 
					
						Drive Current Relationship To Input Current:
					
					
						Unequal					
				 
							
					
						MRC:
						The amount of current for which the drive is rated.BGRF
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The amount of current for which the drive is rated.BGRF
					 
					
						Drive Current Rating:
					
					
						2.0 amperes 					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the drive is rated.BGRG
					 
					
						Drive Frequency Rating:
					
					
						400.0 hertz 					
				 
							
					
						MRC:
						An indication of whether the output voltage is the same as,or different from,the input voltage.BGRH
					 
					
						Output/input Voltage Relationship:
					
					
						Not rated					
				 
							
					
						MRC:
						An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
					 
					
						Contact Operation Sequence:
					
					
						Breaks before makes					
				 
							
					
						MRC:
						The value,or range of values,for which the contact is rated.BGRL
					 
					
						Contact Voltage Rating:
					
					
						10.0 ac pounds per hour with retaining chain					
				 
							
					
						MRC:
						The value,or range of values,for which the contact is rated.BGRL
					 
					
						Contact Voltage Rating:
					
					
						10.0 ac volts 					
				 
							
					
						MRC:
						The amount of current for which the contact is rated.BGRM
					 
					
						Contact Current Rating:
					
					
						1.0 milliamperes 					
				 
							
					
						MRC:
						The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
					 
					
						Phase Angle In Deg:
					
					
						83.0					
				 
							
					
						MRC:
						That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
					 
					
						Dwell Time Rating In Deg:
					
					
						170.0 					
				 
							
					
						MRC:
						An indication of whether or not a feature for plug in mounting is provided.BGRS
					 
					
						Plug In Mounting Feature:
					
					