Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Roentgen Rate Meter
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular, surface mounting
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.750 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.250 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic, phenol-formaldehyde
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no. An/pdr-18
MRC:
An indication of whether or not a magnetic shield is included.AHFT
Magnetic Shielding:
Not included
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.180 in. Diameter mtg holes spaced on 1.938 in. By 3.469 in. Mtg centers
MRC:
The increment of measure represented by the marking/s/ on the item.ANBJ
Graduation Unit:
40.0 milliroentgens
MRC:
An indication of the type of meter.ANTH
Meter Type:
Mounted
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+500.0 milliroentgens
MRC:
An indication of the meter design.APSL
Meter Style:
Panel
MRC:
An indication of the sensitivity of the item.APSM
Err Default:
Err default
MRC:
An indication of the sensitivity of the item.APSM
Sensitivity:
20 ua sensitivity at full scal deflection
MRC:
An indication of the panel for which the item is designed.APSN
Panel For Which Designed:
Nonmagnetic
MRC:
An indication of whether or not the dial scale markings are luminous.APSQ
Dial Scale Marking Luminosity:
Nonluminous
MRC:
A measurement between specified points of the meter to the panel, in distinction from height.APSS
Err Default:
Err default
MRC:
A measurement between specified points of the meter to the panel, in distinction from height.APSS
Meter Depth To Panel:
1.562 inches