Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Frequency Shift Converter
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Steel
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Salt spray resistant
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+55.0
MRC:
The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
Vibration Resistance Amplitude:
0.1 inches total excursion
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
15.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
Not rated
MRC:
The numeric value of the life expectancy of the item.AFHH
Average Life Rating:
90000.0
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Hours
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
90000.0
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/alr-69 peculiar
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
25000.0 feet
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
Not rated
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
Not rated
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
12.000 volts any acceptable preset
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
15.000 volts any acceptable preset
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
50.000 volts any acceptable preset
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
100.0 milliamperes
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
200.0 milliamperes
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
350.0 milliamperes
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
50.0 milliamperes
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
Not rated
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
Not rated
MRC:
The maximum time an item will continuously run,expressed in hours.BJBM
Maximum Continuous Operating Time In Hours:
Not rated
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
5.8 single voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
8.4 single voltage err-100
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Counter measures set