Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					 Nonwire Wound Variable Resistor				
			 
			
										
					
						MRC:
						The number of individual elements.AAPN
					 
					
						Section Quantity:
					
					
						6					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical servo mounted					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
					 
					
						Pilot Diameter:
					
					
						0.96800 inches 					
				 
							
					
						MRC:
						The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
					 
					
						Pilot Length:
					
					
						0.06200 inches 					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.910 inches 					
				 
							
					
					
						Undercut Width:
					
					
						0.05700 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						1.06200 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
					 
					
						Shaft Diameter:
					
					
						0.124 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft,in distinction from width.ABXF
					 
					
						Shaft Length:
					
					
						0.625 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.28500 inches 					
				 
							
					
					
						Mounting Lip Diameter:
					
					
						1.06200 inches 					
				 
							
					
					
						Mounting Lip Depth:
					
					
						0.03100 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
					 
					
						Shaft Style:
					
					
						Round					
				 
							
					
						MRC:
						Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
					 
					
						Actuator Type:
					
					
						Single shaft					
				 
							
					
						MRC:
						The position of the terminal/s/ for making connection to an item.APXH
					 
					
						Terminal Location:
					
					
						Radially positioned over more than half the circumference					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Clamp ring					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Nonmetallic shaft					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						1.000 percent,  rated amperes c drop siding					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						10.000 percent,  rated amperes c and better finish					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						10.000 percent,  rated amperes c and better select					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						10.000 percent,  rated amperes c finish					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						2.000 kilohms 2nd section					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						20.000 kilohms 4th section					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
					 
					
						Resistance Tolerance Per Section In Percent:
					
					
						-10.0 to 10.0 single section