Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.600 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.940 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.460 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
15.0 dc pounds per hour wet 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc pounds per hour wet 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc pounds per hour wet 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
400.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+65.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.5 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.0 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.0 dc amperes 3rd power output
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Limiting current 1st power output
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Limiting current 2nd power output
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Limiting current 3rd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
2.0 millivolts peak 2nd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
2.0 millivolts peak 3rd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
2.0 millivolts peak 1st power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Screw single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
3 single operating power rqmt