Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
12.300 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.560 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.000 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
103.5 ac volts single operating power rqmt and 126.5 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
110.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
15.0 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-100.0 dc volts 6th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-15.0 dc volts 5th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
28.0 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 4th power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 440.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-10.0/+85.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.3 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-0.3 dc amperes 6th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-1.3 dc amperes 5th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.0 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
5.0 dc amperes 4th power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
16 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip single power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
3 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
61.0