Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Has cover; weapon system essential
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.920 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.947 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.700 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.700 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.219 inches single mounting facility
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
Center To Center Distance Between Mounting Facilities Parallel To Height:
3.947 inches single mounting facility
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Aircraft, awacs, e-3a; support equipment, e-3a aircraft
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole single mounting facility
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Rectangular single mounting facility
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
18.0 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
400.0 amperes ac resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
30.0 ac
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
1.5 amperes ac resistive load