Attenuator, microwave, microstrip; fungus, humidity, shock, and vibration resistant
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Fixed Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular terminal/terminals on three surfaces
MRC:
The element,compound,or mixture of which the terminal is fabricated.ABDM
Terminal Material:
Beryllium copper
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.575 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.040 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.310 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+150.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
B-1b
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.25
MRC:
The total opposition (resistive and reactive) which the item offers to the admittance of an entering flow of alternating current,expressed in ohms.AHTY
Input Impedance Rating In Ohms:
50.0
MRC:
The total opposition /resistive and reactive/ which the output of the item provides to match,for maximum transfer of energy,the input impedance of another item,expressed in ohms.AHTZ
Output Impedance Rating In Ohms:
50.0
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
0.1 watts average
MRC:
The decrease in the strength of the radio frequency signals,expressed in decibels.AJDK
Rf Signal Attenuation In Decibels:
8.0
MRC:
The limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.ASYN
Attenuation Accuracy In Decibels:
-0.10/+0.10
MRC:
Indicates the type and number of terminal(s) for providing electrical connection.BBHS
Terminal Type And Quantity:
3 tab, solder lug
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 0.000 hertz and 2.000 gigahertz