Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Pulse Delay Oscillator				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						Between 5.215 inches and 5.235 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						Between 0.572 inches and 0.592 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						Between 2.840 inches and 2.860 inches 					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						Not rated					
				 
							
					
						MRC:
						The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
					 
					
						Shock Resistance Rating In Gravitational Units:
					
					
						Not rated					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-62.0/+85.0 degrees fahrenheit					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Not rated					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Irs-alr46/69					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Rectangular or square					
				 
							
					
						MRC:
						A designation assigned to the item for purpose of ready identification.AJKH
					 
					
						Identification Designator:
					
					
						40145-14-97384					
				 
							
					
						MRC:
						The maximum altitude at which the item is rated to function.AKAE
					 
					
						Maximum Operating Altitude Rating:
					
					
						15000.000 feet					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Open					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Mechanical					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						42.5 hertz  output channel err-100 and 440.0 hertz  output channel err-100					
				 
							
					
						MRC:
						The decrease in strength of an electrical impulse,expressed in decibels.BHTH
					 
					
						Attenuation In Decibels:
					
					
						Not rated					
				 
							
					
						MRC:
						The rated average power for each channel.BHTJ
					 
					
						Average Power Rating Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The increase in energy from the input to the output.BHTL
					 
					
						Overall Gain:
					
					
						Not rated					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The maximum absolute peak value of the pulse per channel.BHTW
					 
					
						Pulse Peak Amplitude Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						Indicates the type of signal data per channel.BHTZ
					 
					
						Signal Data Type Per Channel:
					
					
						Output channel pulse delay					
				 
							
					
						MRC:
						The physical configuration of the output wave.BJBJ
					 
					
						Output Wave Shape:
					
					
						Pulse,  sweep					
				 
							
					
						MRC:
						The maximum time an item will continuously run,expressed in hours.BJBM
					 
					
						Maximum Continuous Operating Time In Hours:
					
					
						Not rated					
				 
							
					
						MRC:
						A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
					 
					
						Reference Number Differentiating Characteristics:
					
					
						As differentiated by the source control dwg no.58744-90014