Teilenummer 601000-05

Line Electro-mechanical Actuator

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
601000-05
Entmilitarisierung:
Yes - DEMIL/MLI
Lagerfähigkeit:
Maßeinheit:
NIIN:
007819702
NSN
Nationale Bestandsnummer:
1680-00-781-9702 1680007819702
TXT
Beschreibung:
Line Electro-mechanical Actuator
INC
INC
Artikelname-Code:
10957
INC
COM
Beachtung:
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit and 300.0 degrees fahrenheit
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.8
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
Between 2.440 inches and 2.530 inches
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
675.0 pounds operating err-100
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
800.0 pounds operating err-100
MRC:
The compression stress applied to the item under load conditions.AWTC
Compression Load Rating:
1000.0 pounds operating
MRC:
The rate of linear travel per unit of time.AWTE
Rated Stroke Velocity:
2.530 inches per minute
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
3.0 minutes on and 17.0 minutes off
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0