Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Engine Generator Regulator				
			 
			
										
					
						MRC:
						The number of terminals for providing electrical connection to the item.AARA
					 
					
						Terminal Quantity:
					
					
						3					
				 
							
					
						MRC:
						Indicates the type of terminals for providing electrical connection to the item.AARB
					 
					
						Terminal Type:
					
					
						Screw					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
					 
					
						Mounting Hole Diameter:
					
					
						0.278 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the mounting.ADER
					 
					
						Mounting Style:
					
					
						Three hole triangular					
				 
							
					
					
						Distance Between Holes Along Width:
					
					
						1.500 inches 					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Corrosion resistant and fungus resistant					
				 
							
					
						MRC:
						An indication of whether or not the item is provided with a self-contained shock mount.AGBC
					 
					
						Shock Mount:
					
					
						Not provided					
				 
							
					
						MRC:
						An indication of whether or not shielding against radio interference is provided.ALBH
					 
					
						Radio Interference Shielding:
					
					
						Not provided					
				 
							
					
						MRC:
						The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
					 
					
						Output Voltage Rating In Volts:
					
					
						Between 27.5 and 29.4 					
				 
							
					
						MRC:
						The electrical voltage of the system for which the item is designed.ANYC
					 
					
						System Voltage Rating:
					
					
						24.0					
				 
							
					
						MRC:
						Indicates the type of ground the electrical system utilizes.ANYD
					 
					
						System Ground Polarity:
					
					
						Positive					
				 
							
					
						MRC:
						Indicates the type of device used to maintain a constant voltage.ANYE
					 
					
						Voltage Regulator Unit Type:
					
					
						Wire wound coil					
				 
							
					
						MRC:
						The number of individual voltage regulator units contained in the item.ANYH
					 
					
						Voltage Regulator Unit Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of device used to limit the current output to the maximum safe value.ANYJ
					 
					
						Current Regulator Unit Type:
					
					
						Wire wound coil					
				 
							
					
						MRC:
						The number of individual current regulator units contained in the item.ANYK
					 
					
						Current Regulator Unit Quantity:
					
					
						1					
				 
							
					
						MRC:
						The current the item will permit to pass,expressed in amperes.ANYP
					 
					
						Output Current Rating In Amps:
					
					
						Between 16.0 and 20.0 					
				 
							
					
						MRC:
						Indicates the type of device used to close and open (break) the circuit.ANYR
					 
					
						Circuit Control Device Type:
					
					
						Cutout relay					
				 
							
					
						MRC:
						The cut-in voltage/s/ required to close the circuit.ANYS
					 
					
						Cut-in Voltage Rating:
					
					
						Between 24.0 and 27.0 					
				 
							
					
						MRC:
						An indication of whether or not a reverse current overload circuit breaker is included.ANZB
					 
					
						Reverse Current Overload Circuit Breaker:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a field relay unit is included.ANZC
					 
					
						Field Relay Unit:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not the terminal(s) is encased.ANZE
					 
					
						Terminal Encasement:
					
					
						Not encased					
				 
							
					
					
						Center To Center Distance Between Holes Along Width And Hole Along Length:
					
					