Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Transformer
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield brought out to terminal single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
5.750 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.375 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
3.355 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
6 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 8 secondary single component
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32 single group
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.164 inches single group
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc single group
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
27 standoff, threaded stud