Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Delay Line
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Not rated
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
6.417 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.690 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+75.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0 to 75.0 degrees celsius
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Not rated
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel case
MRC:
The plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.ANNR
Surface Treatment And Location:
Enamel, mil-e-15090, type 1, class 2 case
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
45.000 kilohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
45.000 kilohms
MRC:
The differences between limiting frequencies of a frequency band.APQL
Frequency Bandwidth:
Not rated
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
0.719 inches
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Connector
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Inductance
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Tapped
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
94.400 microseconds single section
MRC:
The number of segments into which a section is divided.CCDR
Segment Quantity Per Section:
4 single section
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
11.200 microseconds single section 1st segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
21.700 microseconds single section 2nd segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
30.400 microseconds single section 3rd segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
31.100 microseconds single section 4th segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
11.200 microseconds single section 1st segment
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
21.700 microseconds single section 2nd segment
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
31.100 microseconds single section 4th segment
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
30.400 microseconds single section 3rd segment
MRC:
The change in delay as a result of the temperature change per degree celsius.CCDT
Delay Time Variation Per Deg Celsius:
Not rated
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
Not rated
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
1 connector, receptacle
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Except testing, multiapplication