Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Forty-one filtered functions with y-type insert position
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Interfere Filter				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.187 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.710 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						1.710 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.125 inches 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
					
					
						1.271 inches 					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						+10.0/+500.0					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
					
					
						1.271 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-55.0/+125.0 degrees celsius					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 1st radio interference50.0 ohms 2nd radio interference50.0 ohms 3rd radio interference50.0 ohms 4th radio interference50.0 ohms 5th radio interference50.0 ohms 6th radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 1st radio interference50.0 ohms 2nd radio interference50.0 ohms 3rd radio interference50.0 ohms 4th radio interference50.0 ohms 5th radio interference50.0 ohms 6th radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 1st radio interference400.0 2nd radio interference400.0 3rd radio interference400.0 4th radio interference400.0 5th radio interference400.0 6th radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						5.0 1st radio interference5.0 2nd radio interference5.0 3rd radio interference5.0 5th radio interference5.0 4th radio interference5.0 6th radio interference					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						2.5 volts ac 1st radio interference and 8.0 volts dc 1st radio interference2.5 volts ac 2nd radio interference and 8.0 volts dc 2nd radio interference2.5 volts ac 3rd radio interference and 8.0 volts dc 3rd radio interference2.5 volts ac 4th radio interference and 8.0 volts dc 4th radio interference2.5 volts ac 5th radio interference and 8.0 volts dc 5th radio interference2.5 volts ac 6th radio interference and 8.0 volts dc 6th radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 1st radio interference inductance-capacitance 2nd radio interference inductance-capacitance 3rd radio interference inductance-capacitance 4th radio interference inductance-capacitance 5th radio interference inductance-capacitance 6th radio interference					
				 
							
					
						MRC:
						The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
					 
					
						Input Terminal Manufacturer Code:
					
					
						59610					
				 
							
					
						MRC:
						The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
					 
					
						Input Terminal Identification:
					
					
						Mil-c-26482					
				 
							
					
						MRC:
						The identifying numeric code of the originator that controls or manufactures the output terminal.AHBS
					 
					
						Output Terminal Manufacturer Code:
					
					
						59610					
				 
							
					
						MRC:
						The specification,standard,or manufacturers identification number or symbol used to identify the output terminal.AHBT
					 
					
						Output Terminal Identification:
					
					
						Mil-c-26482					
				 
							
					
						MRC:
						The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
					 
					
						Maximum Tempurature Rise:
					
					
						25.0 degrees celsius					
				 
							
					
						MRC:
						The specified points in the frequency spectrum at which insertion losses (as a function of frequency) under full load are measured,expressed in megahertz.AHCJ
					 
					
						Full Load Insertion Loss Frequencies In Megahertz:
					
					
						0.0 and 0.1 and 1.0 and 10.0 and 100.0 and 1000.0					
				 
							
					
						MRC:
						The least permissible values for attenuation of spurious or unwanted signals at designated points in the frequency spectrum,expressed in decibels.AHCK
					 
					
						Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
					
					
						3.0 and 10.0 and 10.0 and 10.0 and 50.0 and 50.0					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Hermetically sealed					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 unthreaded hole					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Moisture resistant and shock resistant					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						41 friction w/grounding strap and pin input-output					
				 
							
					
						MRC:
						The maximum alternating current root mean square voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CQDZ
					 
					
						Maximum Dielectric Withstanding Ac Rms Voltage:
					
					
						1.2 kilovolts at sea level					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						250.0 volts ac 2nd radio interference 2nd function and 250.0 volts ac 4th radio interference 4th function and 250.0 volts ac 5th radio interference 5th function and 250.0 volts ac 1st radio interference 1st function and 250.0 volts ac 3rd radio interference 3rd function and 800.0 volts dc 4th radio interference 4th function800.0 volts dc 2nd radio interference 2nd function800.0 volts dc 1st radio interference 1st function800.0 volts dc 3rd radio interference 3rd function800.0 volts dc 5th radio interference 5th function250.0 volts ac 6th radio interference 6th function and 800.0 volts dc 6th radio interference 6th function					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
					 
					
						Body Material:
					
					
						Metal					
				 
							
					
						MRC:
						The maximum direct current voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CRDC
					 
					
						Maximum Dielectric Withstanding Dc Voltage:
					
					
						1.2 kilovolts at sea level					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the body is plated,dipped and/or coated. the treatment is designed to protect the body surface/s/ and cannot be wiped off.CRST
					 
					
						Body Surface Treatment:
					
					
						Cadmium					
				 
							
					
						MRC:
						An indication of the precious material and its location in the item.PMLC
					 
					
						Precious Material And Location:
					
					
						Contact surfaces gold					
				 
							
					
						MRC:
						Identification of the precious material contained in the item.PRMT
					 
					
						Precious Material:
					
					
						Gold					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Filter connector