Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Includes 2 ground tabs
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Band Pass Filter
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.580 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.750 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.625 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.440 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+100.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Radio set an/prc-113
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
30.1 megahertz blank
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms blank
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms blank
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Crystal blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
5 terminal
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
4.0 blank
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 pin input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 pin output 2nd function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
3 pin ground 3rd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
30.0305 megahertz blank and 30.0645 megahertz blank and 30.1355 megahertz blank and 30.1695 megahertz blank
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
30.0645 megahertz blank and 30.1355 megahertz blank
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 blank and 60.0 blank
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on one surface