					Electrical Coil				
			 
			
										
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The number of turns of conductive material forming the winding.ABHY
					 
					
						Turn Quantity:
					
					
						13 single component 2nd winding					
				 
							
					
						MRC:
						The number of turns of conductive material forming the winding.ABHY
					 
					
						Turn Quantity:
					
					
						230 single component 1st winding					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
					 
					
						Mounting Slot Width:
					
					
						1.850 inches  single group					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						5.250 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						3.620 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						4.460 inches 					
				 
							
					
						MRC:
						The number of individual /not electrically connected/ windings.AKDX
					 
					
						Winding Quantity:
					
					
						2 single component					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Open					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						1 single group					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Slot single group					
				 
							
					
						MRC:
						The means by which the rating is determined.BKPL
					 
					
						Rating Method:
					
					
						Winding turns single component all winding					
				 
							
					
						MRC:
						The size of the conductor which forms the winding on the item.CQPZ
					 
					
						Winding Conductor Size:
					
					
						0.02010 inches american wire gage single component 2nd winding					
				 
							
					
						MRC:
						The size of the conductor which forms the winding on the item.CQPZ
					 
					
						Winding Conductor Size:
					
					
						0.04030 inches american wire gage single component 1st winding					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						4 wire lead