Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Cam Actuated Fuel Pump
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Nonstandard
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.562 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.187 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.188 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Direct cam
MRC:
An indication of whether or not a feature is included for the item to be operated in a specified depth of water without malfunction.AGEB
Fording Feature:
Not included
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Gasket
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
0.250 inches
MRC:
An indication of whether or not a vacuum booster is included.BJJC
Vacuum Booster:
Not included
MRC:
An indication of whether or not a fuel filter is included.BJJG
Fuel Filter:
Not included
MRC:
An indication of whether or not a priming lever is included.BJJJ
Priming Lever:
Not included
MRC:
The maximum static pressure of the item above the outlet height.BJJK
Maximum Static Pressure Above Outlet Height:
3 psi min to @4 psi maximum at 16 in. At 1800 rpm
MRC:
The distance from the mounting face of the pump to the center of the actuator.BJJL
Distance From Pump Mounting Face To Actuator Center:
1.488 in. To center line of cam
MRC:
Indicates the type and size of the inlet connection(s) on the item.BJJM
Inlet Connection Type/size:
Fvel 1/8-27 npsf internal dryseal pipe thd
MRC:
Indicates the type and size of the outlet connection(s) on the item.BJJN
Outlet Connection Type/size:
Fuel 1/8-27 npsf internal dryseal pipe thd
MRC:
An indication of whether or not a drain facility(ies) is included.BJJP
Drain Facility:
Not included