Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Pressure Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.300 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.620 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
2.370 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.300 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
Between 0.219 inches and 0.233 inches
MRC:
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
Pressure Switch Type:
Gage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket and unthreaded hole
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
12.000 cubic inches
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Wire lead
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
15.0 amperes resistive load and 15.0 amperes inductive load first voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
15.0 amperes resistive load and 15.0 amperes inductive load second voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
15.0 amperes resistive load and 15.0 amperes inductive load third voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
4.0 amperes resistive load and 2.0 amperes inductive load fifth voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
6.0 amperes resistive load and 5.0 amperes inductive load fourth voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point adjustable
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
+23.00 to 35.00 actuation point pounds per square inch
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
Internal actuation point screw
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
125.0 ac at sea level first voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
125.0 dc at sea level fifth voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
28.0 dc at sea level fourth voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
480.0 ac at sea level third voltage
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 first voltage
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 second voltage
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 third voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Cylindrical w/mounting lugs